Wiring check

Five questions about your home’s wiring, and a plain answer on what is worth doing next. It is general guidance from your answers, not an inspection, and nothing is sent anywhere unless you choose to send it.

  • Questions 05
  • Guidance IET and the 2020 Regulations
  • Sent Only if you choose

The check

Five questions

Question 1 of 5Whose home is it?

This decides which inspection rule applies.

Question 2 of 5Roughly when was it last rewired?

A guess is fine. If it has never been rewired, go by when the house was built.

Question 3 of 5When did it last have an EICR?

An Electrical Installation Condition Report: an inspection and test of the whole installation, written up with any problems coded.

Question 4 of 5Which looks most like your fuse board?

It is usually under the stairs, in a hall cupboard or in the garage.

Question 5 of 5Have you noticed any of these?

Tick all that apply.

The check

The step-by-step check needs JavaScript. Everything it is based on is set out below, and you can always ask us or send a photo of the board on WhatsApp.

How it works

What the answers tell us

The check is built from the rules and guidance below. Read it on its own if you prefer: it is the same advice.

01

Who you are

Private landlords in England must have the electrical installation inspected and tested at least every five years, under the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020. They must give tenants a copy of the report, and have any remedial work it requires done within 28 days, or sooner if the report says so.

If you own the home and live in it, IET guidance recommends a periodic inspection at least every ten years.

If the home is changing hands, the same guidance recommends an inspection then too. For a buyer it shows what they are taking on; for a seller it answers the questions before a survey raises them.

02

When it was last rewired

Age on its own does not decide anything, but it tells you what kind of cable to expect. Rubber-insulated cable, used before PVC became standard, goes brittle and cracks when it is disturbed. Lead-sheathed cable is older still. Early PVC is more durable, but it degrades with heat over decades.

Round here, a great many houses went up between the 1950s and the 1980s, and plenty still have their original wiring. An inspection records what is actually in the walls, and whether a rewire is the job to plan for.

03

The last EICR

An Electrical Installation Condition Report is the written result of an inspection and test of the whole installation. Anything found is coded:

  • C1 danger present.
  • C2 potentially dangerous.
  • C3 improvement recommended.
  • FI further investigation required.

The report also gives the date the next inspection is due. If you cannot find yours, or nobody knows when the last one was, that is an answer in itself.

04

The fuse board

Modern regulations require 30 mA RCD protection for most circuits in a home, including the sockets. An RCD switches off when current leaks to earth, which is what happens when someone touches something live. A rewirable fuse box gives none; nor does an older board with circuit breakers but no RCD.

An RCBO does the RCD’s job and protects against overload too, for one circuit, so a fault on one circuit does not take out half the house. Since 2016, new consumer units in homes have had to be in a non-combustible enclosure, in practice steel. A plastic board from before then is not automatically unsafe, but its replacement will be steel. More on consumer units.

A Rewirable fuses

Fuse box with rewirable fusesA wooden board with a separate main switch and a fuse box of five fuse carriers, one pulled out. Each carrier holds a length of fuse wire. Nothing on it gives RCD protection.

A fuse box with pull-out carriers and fuse wire. No RCD protection at all.

B Older board, no RCD

Older plastic board without RCDsA plastic consumer unit with a main switch and a row of six circuit breakers. There is no RCD and no test button anywhere on the board.

Circuit breakers, which protect the cables, but nothing that switches off when current leaks to earth.

C RCDs or RCBOs

Modern board with RCD protectionA steel consumer unit with a main switch, a surge protection device and a row of RCBOs, each with its own test button.

A board with RCD protection: look for test buttons marked T or Test. Newer ones are steel.

D Not sure

Not sureA closed cupboard door with a question mark: the board is hidden, or you are not sure what it is. ?

Hidden in a cupboard or hard to read. A photo on WhatsApp settles it.

Fig. 1The four answers to question 4, drawn. Examples, not to scale: boards vary, and a photo of yours is the surest way to tell.
05

Warning signs, and what they suggest

  • Round-pin sockets usually belong to a very old installation. Worth an inspection, and a rewire may be the bigger job to plan for.
  • Black rubber or fabric-covered flex or cable is older than PVC. Rubber insulation cracks when it is disturbed, so leave it alone and have it inspected.
  • Scorch marks mean something has got hot enough to burn, often a loose connection or an overloaded socket.
  • Sockets or plugs that get warm point to a loose connection or too much load.
  • Buzzing or crackling from a socket, switch or the board usually means a poor connection or arcing.
  • Fuses blowing or breakers tripping often means something on that circuit has a fault, or it is overloaded. Fault finding tracks down which.
  • Lights that flicker can be the lamp or the fitting. If several do it, or it comes with buzzing, there may be a loose connection.
06

When to switch off and call

If a socket, plug, switch or the board is hot, scorched, buzzing or smells of burning, stop using it. If you can reach the consumer unit safely, switch off that circuit, or the main switch, and call us on 07711 031164.

Do nottake covers off, or touch anything that is scorched or wet. Leave it switched off until it has been looked at.

Questions

The check, asked and answered

Something else on your mind? Ask us.

Is the wiring check a substitute for an EICR?

No. It is general guidance based on your answers. Only an inspection and test of the installation, written up as an Electrical Installation Condition Report, tells you its actual condition.

How often should a home have an electrical inspection?

For an owner-occupied home, IET guidance recommends at least every ten years, and when the property changes hands. Private landlords in England must have one at least every five years, and give the tenants a copy of the report.

What do the codes on an EICR mean?

C1 means danger present. C2 means potentially dangerous. C3 means improvement recommended. FI means further investigation required. The report explains each observation and gives a date for the next inspection.

What happens when I send my answers?

They go into the enquiry form as a message, with the service that fits best already chosen. You can change anything before you send it, and nothing reaches us until you press send.

My board has a test button. Do I need to do anything?

Press it as often as the notice on the board says. It checks the RCD still trips. If it does not trip, or will not reset afterwards, get it looked at.

Registration and standards

  • Scheme NAPIT registered Registered electrical installer
  • Standard Work to BS 7671 The IET Wiring Regulations
  • Building Regulations Part P notified Notifiable work reported to building control

Get in touch

Send us a photo of the job.

A photo of the fuse board, the fault or the room, sent on WhatsApp, is often the quickest way to start. Or call, or use the enquiry form and we will come back to you.

  1. 01A photo of the fuse board, or of the problem
  2. 02Your postcode, so we know where the job is
  3. 03A sentence on what you would like done