Underfloor heating and controls

Electric underfloor heating on its own RCD-protected circuit, with insulation boards, a floor probe and a thermostat in the right place. Plus the thermostats, programmers and smart controls that run the rest of your heating, wired alongside your heating engineer. For homes in Sandhurst, Camberley, Bracknell and Ascot.

  • Service 08 / 09
  • Certificate EIC
  • RCD 30 mA
  • Gas work Not ours
01

Mat or loose cable

Electric underfloor heating is a heating cable laid under the floor finish, usually tiles. A mat has the cable fixed to a mesh at a set spacing, so it rolls out quickly over a regular floor. Loose cable is laid by hand at a spacing to suit the room, which makes it better for awkward shapes and the gaps between fittings.

Either way, it goes only in the open floor. It is never laid under the bath, the WC, a basin pedestal or kitchen units, where the heat cannot get out.

Wet underfloor heating, with water pipes from a boiler or heat pump, is a different system. The pipework is for your heating engineer; the wiring centre, pump and thermostats are electrical, and that part is ours.

02

Insulation boards

On a concrete floor, a lot of the heat would go down into the slab instead of up into the room. Insulation boards laid first stop that: the floor warms faster, and the heat goes where you want it.

Boards add height, so the build-up is agreed with the tiler before anything is laid, to meet the door threshold and the floor of the next room.

03

The floor probe

The thermostat needs to know how warm the floor is, and the floor probe tells it. The probe is laid between two runs of cable, an equal distance from each, usually in a thin conduit so it can be replaced without lifting tiles.

It also protects the floor. Wood, laminate and vinyl all have a maximum temperature, and the thermostat uses the probe to stay below it.

The heating cable is tested before it is laid, once it is down, and again after tiling: its resistance should match the maker’s figure and its insulation should be sound. A damaged cable is far easier to deal with before the tiles go on.

04

A circuit of its own, with RCD protection

Underfloor heating gets a dedicated circuit from the consumer unit, sized for the heating’s load, with 30 mA RCD protection. Heating cables have an earthed metal screen, so damage to the cable trips the RCD instead of leaving the floor live.

A new circuit is notifiable under Part P and gets an Electrical Installation Certificate with its test results. If the board has no spare way or no RCD protection, the quote says what is needed first.

05

In a bathroom

Most electric underfloor heating goes into bathrooms and en-suites, so the bathroom zones apply. The heating itself is made to go in the floor under them. The thermostat is not: it goes outside the zones, usually on the wall just outside the door, with the cold tail and the probe running to it in the wall.

Work in a bathroom’s special location is notifiable under Part P, and the notification is made for you.

Plan A small bathroom

Underfloor heating mat in a bathroom, planPlan of a small bathroom with a bath along one wall, a basin and a WC. Insulation boards cover the whole floor. The heating mat is laid only in the open floor, not under the bath, basin or WC. Its cold tail and a floor probe, laid between two runs of cable, go out through the wall to a thermostat on the landing side, which is fed from its own circuit. BATH BASIN WC FROM CU LANDING A B C D E F
  1. AHeating mat, in the open floor only.
  2. BFloor probe, in a conduit between two runs of cable.
  3. CCold tail: the unheated lead from the mat to the thermostat.
  4. DThermostat outside the bathroom, fed from its own circuit.
  5. EInsulation boards over the whole floor.
  6. FNo heating under the bath, the basin or the WC.

Section The floor build-up

Section through a heated floorSection through the floor: tiles on adhesive, the heating cable and the floor probe in the adhesive bed, an insulation board beneath, and the concrete subfloor at the bottom. Arrows show the heat going up into the room. TILE ADHESIVE CABLE BOARD SUBFLOOR B
  1. BFloor probe, level with the cable and between two runs.
  2. !Board under the heating, so the heat goes up into the room and not down into the slab.
Fig. 1An underfloor heating mat in a small bathroom, and a section through the floor. An example, not to scale: every layout is planned around the room.
06

Thermostats and smart controls

A room thermostat switches the heating by the air temperature. An underfloor heating thermostat usually reads the floor probe, the air, or both. Programmable thermostats add times and temperatures for each day. Smart thermostats do the same from an app, and can be grouped so that each room is controlled on its own.

Most of the wiring is simple. What matters is that the thermostat suits what it controls: an underfloor heating thermostat for an electric floor, one that works with your boiler for a wet system, and a smart thermostat where it has the signal it needs.

07

Wiring centres and programmers

A boiler-fed heating system is held together electrically by a wiring centre: a junction box where the boiler, pump, motorised valves, room thermostat, cylinder thermostat and programmer all meet. The two common layouts are known as S‑plan, with a two-port valve for each zone, and Y‑plan, with one three-port valve shared by the heating and the hot water.

Replacing an old programmer with a smart control, adding a heating zone, or finding out why the hot water comes on but the heating does not, are all jobs on the wiring centre. Each starts with tracing what is already there, because older wiring centres have often been altered more than once.

08

Working with your heating engineer

We do the wiring, not the gas. Anything on the gas supply or the boiler’s gas side is for a Gas Safe registered engineer.

On a new boiler or a new heating system, the electrical side is ours: the boiler’s fused supply, the wiring centre, valves, pump, thermostats and controls, planned with the heating engineer so the two halves meet. If your heating engineer has asked for an electrician, send us their wiring diagram or the boiler’s make and model, and we will tell you what is involved.

Good to know

Heating controls
  • Heating before tiles. The cable is laid and tested before the tiler starts, and tested again after.
  • Nothing under fixed fittings. The bath, the WC and the units stand on unheated floor.
  • Insulate first. Boards under the heating send the heat up into the room.
  • Check your floor finish. Wood, laminate and vinyl have a temperature limit, and the probe keeps below it.
  • The thermostat goes outside the zones, usually just outside the bathroom door.
  • Wiring, not gas. Gas work is for a Gas Safe registered engineer.

Questions

Heating controls, asked and answered

Something else on your mind? Ask us.

Can underfloor heating go in a bathroom?

Yes, it is made for it. The heating goes in the open floor, the thermostat goes outside the zones, the circuit has 30 mA RCD protection, and the work is notifiable under Part P.

Mat or loose cable?

Both do the same job. A mat is quicker to lay on a regular floor. Loose cable is better for awkward shapes and the small gaps between fittings.

Do I need insulation boards?

On a concrete floor they make a big difference. Without them a lot of the heat goes down into the slab, and the floor is slow to warm up.

Can you fit a smart thermostat to my boiler?

That depends on the boiler and the controls already there. Send a photo of the thermostat, the programmer and the wiring centre if you can find it, with the boiler’s make and model, and we will tell you what is involved. Any gas work is for a Gas Safe registered engineer.

What certificate will I get?

A new circuit for underfloor heating gets an Electrical Installation Certificate and is notified under Part P, and you receive a Building Regulations compliance certificate. A smaller job on an existing circuit, such as moving a thermostat, gets a Minor Electrical Installation Works Certificate.

Registration and standards

  • Scheme NAPIT registered Registered electrical installer
  • Standard Work to BS 7671 The IET Wiring Regulations
  • Building Regulations Part P notified Notifiable work reported to building control